LowĪctivity emitters are used and it is necessary to create maximum Purpose - radiographic control: metals (including non-ferrous) welded and soldered joints, plastics, ceramics, rubber cast components and composites steel objects of small thickness Used when: Faster film D8 does not provide the desired sensitivity Work is underway with pulsed and constant potential x-ray machines, radionuclide sources and accelerators. Thicknesses and intensities, places with a complex configuration, using Possible to obtain contrast images when translucent areas with different

D7įilm registers a wide range of radiation intensities, making it
#AGFA STRUCTURIX D7 PB ROLLPAC ISO#
Sensitivity GOST 7512-82 and the control level of class 'B' GOST ISOġ7636-1, corresponds to class C5 film systems according to ISO 11699-1. Is high-contrast and meets the requirements of class 1 of control Roll length - 90 m, film width - 70 mm / 100 mm. Great for tanks, pipelines and other facilities with en. No cassettes required, can be cut to any length. Package: Pb Rollpac is a roll pack with a Pb screen (thickness 0.027 mm), opaque, protected from water and oil and grease. indicators of X-ray machines, which were obtained using D7 film, are taken as a standard. It is used by equipment manufacturers as the main one in nomograms for evaluating the performance of X-ray machines. X-ray film AGFA D7 Pb Rollpack 100mm x 90m The most common X-ray industrial fine grain film among the D-series.